3D Anterior Segment Analyzer

- Generate 28/60/100 ultra-high-definition Scheimpflug images of ocular anterior segment
- A total of 107,520/230,400/384,000 data analysis points are collected
- Has a growing global population database approximately 3,000 cases
- The optimal-designed functions perfectly meet the needs of multiple ophthalmic scenarios

Product Function

  • Refractive Surgery

  • Refractive Cataract Surgery

  • Contact Lens Fitting

  • Glaucoma Screening

  • ICRS Surgery

Refractive Surgery

Keratoconus Analysis

Keratoconus Analysis

The various keratoconus related parameters provided by Scansys, such as the Refractive 4 Maps, Corneal Thickness Spatial Profile (CTSP), Percentage Thickness Increase (TCI), Keratoconus Index (KCI) of the anterior and posterior corneal surfaces, Case Reference, SVM Classifier, Keratoconus Probability (KCP) and Keratoconus Grading (Grade 0-IV), etc., can help eye-care professionals diagnose keratoconus effectively.

Binocular Contrast of Refractive 4 Maps

Binocular Contrast of Refractive 4 Maps

The corneal morphology of normal people's binocular eyes shows a certain degree of symmetry, while patients with keratoconus often have the disease onset in one eye first. Eye-care professionals can use the binocular contrast function of Scansys to compare the morphology and values of the Refractive 4 Maps of the patient's binocular corneas, thereby improving the keratoconus screening efficiency in the early stage, such as forme fruste keratoconus. It is also possible to determine whether keratoconus progresses by comparing the differences of the same eye of the patient at different time points.

ICL Size Recommendation and Vault Prediction

ICL Size Recommendation and Vault Prediction

Scansys can, based on the analysis of data such as the corneal diameter, corneal curvature, corneal thickness, anterior chamber depth and anterior chamber angle of the patient, intelligently recommend the size of the ICL lenses and predict the range of postoperative vault.

Postoperative ICL Vault Measurement

Postoperative ICL Vault Measurement

Scansys supports capturing high-definition Scheimpflug images at any angle after the ICL surgery to precisely measure the postoperative vault, thereby more objectively evaluating the effect and safety of the surgery.

Wavefront Aberration and Visual Quality Analysis

Wavefront Aberration and Visual Quality Analysis

Scansys provides up to 8-order Zernike wavefront aberration data of the corneal anterior and posterior surfaces and the entire cornea with a maximum diameter of 12mm. Meanwhile, it can also simulate the visual quality image in a more intuitive way through Retinal Imaging, Point Spread Function (PSF) and Modulation Transfer Function (MTF), etc., providing a crucial basis for the preoperative plan design and postoperative visual quality evaluation of customized corneal refractive surgery.

Fourier Analysis

Fourier Analysis

Scansys can decompose the complex corneal topography data of patients into quantitatively analyzable components such as Spherical Component, Decentration Component, Regular Astigmatism Component and Irregularity Component through Fourier Analysis, which can provide more scientific guidance basis for eye-care professionals to design personalized corneal refractive surgery plans.

Refractive Cataract Surgery

Refractive Cataract Surgery


IOL Optimization


Scansys provides key parameters such as three types of corneal refractive power (Simk, Total Corneal Power and True Net Power), Total Corneal Astigmatism, Total Corneal Spherical Aberration, Total Corneal Higher-Order Aberration, the ratio of the curvature radius of the posterior corneal surface to that of the anterior corneal surface, Kappa Angle and Alpha Angle. Combined with the built-in calculators for age optimization of astigmatism and age optimization of spherical aberration, it can truly accomplish the optimization of advanced IOLs and help patients achieve the best visual quality after refractive cataract surgery.



IOL Calculation

Scansys has built-in multiple intraocular lens calculation formulas such as Pearl-DGS (Optional), Jin, SRK-T, Holladay 1, Hoffer Q, etc. and the IOL parameters provided by manufacturers. It can quickly provide the corresponding IOL power for common cataract patients or cataract patients after refractive laser surgeries.

Crystalline Lens Density Analysis

By calculating the gray value in both the cross-sectional and longitudinal sections of the crystalline lens, Scansys can assist eye-care professionals better design the cataract surgeries and the intraoperative operations.

Wavefront Aberration and Visual Quality Analysis

Scansys provides up to 8-order Zernike wavefront aberration data of the corneal anterior and posterior surfaces and the entire cornea with a maximum diameter of 12 mm. Meanwhile, it can also simulate the visual quality image in a more intuitive way through Retinal Imaging, Point Spread Function (PSF) and Modulation Transfer Function (MTF), etc., providing a crucial basis for the preoperative plan design and postoperative visual quality evaluation of refractive cataract surgery.

Contact Lens Fitting


Contact Lens Fitting


Orthokeratology Lens Fitting

Provide the ecc values of the cornea in different directions (nasal, temporal, inferior, superior, flat and steep) and in different diameter ranges (2mm - 10mm), as well as parameters such as corneal curvature and sagittal height, to offer comprehensive data support for orthokeratology lenses fitting.


Contact Lens Simulated Fitting

Scansys allows eye-care professionals to customize the contact lens database. Combined with the corneal parameters of patients, it can simulate the contact lens fitting effect (3D/2D) under the corneal fluorescence staining with slit lamp. Moreover, an ideal fluorescence fitting simulation effect can be obtained through parameter adjustment. This is helpful for beginners to grow rapidly, improve the fitting efficiency of orthokeratology lenses, and avoid the trouble and discomfort caused to patients by changing trial lenses multiple times.

Automatic Calculation of Contact Lens Fitting Parameters

Scansys has a built-in automatic calculation for contact lens fitting , which can help eye-care professionals quickly obtain the fitting parameters of orthokeratology lenses, soft contact lenses or RGP lenses based on the patients' corneal parameters.

Scleral Lens Module (0ptional)

Scansys can capture 60 high-definition Scheimpflug images of corneosclera in a single scan, covering a 16mm-diameter of corneoscleral area. It can display the corneoscleral sagittal height in a 360° panoramic view without any multiple scans and image stitching, and provide 13 key parameters so as to offer comprehensive and accurate data support for scleral lens fitting.

Glaucoma Screening

Anterior Chamber Angle Analysis

Anterior Chamber Angle Analysis

By calculating the gray levels of the anterior chamber and the anterior chamber angle of patients, Scansys can obtain parameters such as Angle Opening Distance (AOD) and Trabecular-Iris Space Area (TISA) and thereby present the distribution trend curve of the original AOD and the linearly fitted distribution trend on both sides of the corneal apex, as well as parameters such as Anterior Chamber Angle, Anterior Chamber Volume, and Anterior Chamber Depth. This is of certain enlightenment significance for the early screening of glaucoma and can also track the effect of laser peripheral iridectomy.

IOP Correction Formula

IOP Correction Formula

Scansys has 5 built-in IOP correction formulas based on corneal thickness, which help eye-care professionals well understand the real IOP of patients and have certain reference value for the diagnosis of glaucoma.

ICRS Surgery

ICRS Implantation Recommendation

ICRS Implantation Recommendation

Scansys is capable of providing a comprehensive set of parameters necessary for creating corneal stromal ring tunnels both through manual dissection (utilizing a corneal stromal ring tunnel dissector) and femtosecond laser dissection based on the corneal morphology of patients, in order to improve the predictability of Intrastromal Corneal Ring Segments (ICRS) implantation and reduce surgical complications.

Expert Video

Dr. Mohamed Hosny

Cairo University, Egypt

Dr. Piotr Kanclerz

Hygeia Clinic, Elbglag, Poland

Dr. Leonardo Torquetti

Centro de Excelência em Oftalmologia, Brazil

Testimonial - What your peers are saying

Dr. Mohamed Hosny

Dr. Mohamed Hosny

Cairo University, Egypt

Scansys enhances the experience of the doctors and patients when we are treating complex cases.​

Dr. Piotr Kanclerz

Dr. Piotr Kanclerz

Hygeia Clinic, Elbglag, Poland

We can accurately assess the morphology of the lesion we are expecting and not only the anterior surface as in corneal topography.

Dr. Leonardo Torquetti

Dr. Leonardo Torquetti

Centro de Excelência em Oftalmologia, Brazil

Scansys is very useful for decision making, surgical planning, so it’s a very powerful machine.

Dr. Mingguang He

Dr. Mingguang He

Centre for Vision Research of Hong Kong Polytechnic University, Hongkong, China

MediWorks has extremely strong product development capabilities. More than ten years ago, I participated in the verification of Scansys anterior segment analysis to ensure that the product truly meets clinical needs.

Dr. Haiying Jin

Dr. Haiying Jin

Shanghai East Hospital Affiliated to Tongji University, Shanghai, China

​Scansys is very helpful for IOL Optimization, especially for the planning of refractive cataract surgery, and it is also very user-friendly for young doctors.

Dr. Zhi Chen

Dr. Zhi Chen

Eye & ENT Hospital of Fudan University, Shanghai, China

The comprehensive scleral lens fitting parameters of Scansys can help doctors quickly understand the patient's corneoscleral morphology and better select trial lenses, and its function is similar to that of AS-OCT.

Dr. Francisco Miguel Cruz

Dr. Francisco Miguel Cruz

Centro Diagnóstico e Tratamento de Tomar, Portugal

I now use Scansys for all my ICL patients, as its WTW measurement is more precise than that of other existing devices and it also suggests the ICL size and the postoperative vault.